Micro Ostwald Viscometer

Micro Ostwald Viscometer 

소량의 점도 측정에 적합한 점도계


Micro Ostwald Viscometer


ν = K · t                               ν = kinematic viscosity in mm²/s 

K = ν / t                               K= constant [mm²/s]

t = ν / K                               t = flow-through time in s

Calibrated with ring marks, with constants and calibraton certificate for manual measurements

Type No.        Order No.        Capillary No.       Capillary Ø i ± 0,01 [mm]         Constant K (approx.)            Measuring range [mm²/s] (approx.)

516 10             285404203                                               0.43                                       0.01                                            0.4 to 6

516 13             285404211                  Ic                              0.60                                       0.03                                            1.2 to 18

516 20             285404228                  II                               0.77                                       0.1                                               4 to 60

516 23             285404236                 IIc                               1.00                                       0.3                                             12 to 180

516 30             285404244                 III                                1.36                                        1                                              40 to 800

Calibrated with ring marks, with constants and calibraton certificate for automatic measurements

Type No.        Order No.        Capillary No.       Capillary Ø i ± 0,01 [mm]         Constant K (approx.)            Measuring range [mm²/s] (approx.)

517 10             285404306                  I                               0.43                                       0.01                                            0.4 to 6

517 13             285404314                  Ic                              0.60                                       0.03                                            1.2 to 18

517 20             285404322                  II                               0.77                                       0.1                                               4 to 60

517 23             285404339                 IIc                               1.00                                       0.3                                             12 to 180

517 30             285404347                 III                                1.36                                        1                                              40 to 800

Not Calibrated without calibraton certificate for relative viscosity

Type No.        Order No.        Capillary No.       Capillary Ø i ± 0,01 [mm]         Constant K (approx.)            Measuring range [mm²/s] (approx.)

518 10             285404409                  I                               0.43                                       0.01                                            0.4 to 6

518 13             285404417                  Ic                              0.60                                       0.03                                            1.2 to 18

518 20             285404425                  II                               0.77                                       0.1                                               4 to 60

518 23             285404433                 IIc                               1.00                                       0.3                                             12 to 180

518 30             285404441                 III                                1.36                                        1                                              40 to 800